17 research outputs found

    The role of ceus in the evaluation of thyroid cancer : From diagnosis to local staging

    Get PDF
    Publisher Copyright: © 2021 by the authors. Licensee MDPI, Basel, Switzerland.Ultrasound often represents the first diagnostic step for thyroid nodule evaluation in clinical practice, but baseline US alone is not always effective enough to achieve thyroid nodule characterization. In the last decades new ultrasound techniques, such as CEUS, have been introduced to evaluate thyroid parenchyma as recommended by EFSUMB guidelines, for use in clinical research field, although its role is not yet clear. Several papers show the potential utility of CEUS in the differential diagnosis of benign and malignant thyroid nodules and in the analysis of lymph node involvement in neoplastic pathology. Therefore, we carried out an evaluation of the literature concerning the role of CEUS in three specific areas: the characterization of the thyroid nodule, the evaluation of minimally invasive treatment and loco‐regional staging of the lymph node in proven thyroid cancer. According to evidence reported, CEUS can also play an operative role in nodular thyroid pathology as it is able to guide ablation procedures on thyroid nodule and metastatic lymph nodes, to assess the radicality of surgery, to evaluate disease relapse at the level of the margins of ablated regions and to monitor the clinical evolution of necrotic areas in immediate post‐treatment setting.publishersversionPeer reviewe

    Preoperative Multiparametric Ultrasound and Fine Needle Aspiration Cytology evaluation of parotid gland tumors : which is the best technique?

    Get PDF
    Publisher Copyright: © 2021 Societatea Romana de Ultrasonografie in Medicina si Biologie. All rights reserved.AIMS: To evaluate the pre-surgical diagnostic value of Multiparametric Ultrasound (MPUS) and Fine Needle Aspiration Cytology (FNAC) in differentiating parotid gland tumors, comparing the results with histology. MATERIALS AND METHODS: The study enrolled 84 patients with parotid gland lesions surgically treated in a single tertiary center and evaluated by MPUS. Each patient underwent FNAC. Histological examination was considered the gold standard. RESULTS: Histology identified 62 benign tumors and 22 malignancies. In the differential diagnosis between malignant and benign lesions, B-mode Ultrasound (US), Color-Doppler US, Contrast-Enhanced US (CEUS), Elastography (USE) and FNAC showed the following values of sensitivity: 82%, 81%, 86%, 77%, 73% respectively; specificity: 97%, 61%, 95%, 71%, 97% respectively; PPV: 90%, 43%, 86%, 50%, 89% respectively; NPV: 93%, 90%, 95%, 88%, 91% respectively; and accuracy: 89%, 71%, 90%, 78%, 84% re-spectively. CONCLUSIONS: CEUS proved to be a valid and accurate method for identifying malignant tumors of parotid gland; the combination of B-mode US with CEUS showed similar diagnostic accuracy, but better sensitivity than CEUS taken alone. USE did not improve the diagnostic performance of the B-mode US, alone or in association with CEUS; however, it revealed the highest diagnostic accuracy in the differentiation between benign lesions. FNAC demonstrated lower values in comparison with CEUS and with USE. Therefore, according to our study, MPUS could be proposed as a valid alternative to FNAC.publishersversionPeer reviewe

    Narrative review of multiparametric ultrasound in parotid gland evaluation

    Get PDF
    Disorders affecting parotid gland represent a heterogeneous group comprising congenital, inflammatory and neoplastic diseases which show a focal or diffuse pattern of appearance. The differentiation of neoplastic from non-neoplastic conditions of parotid glands is pivotal for the diagnostic imaging. Frequently there is evidence of overlapping between the clinical and the imaging appearance of the various pathologies. The parotid gland is also often object of study with the combination of different techniques [ultrasound-computed tomography-magnetic resonance imaging (US-CT-MRI), ex.]. Compared to other dominant methods of medical imaging, US has several advantages providing images in real-time at lower cost, and without harmful use of ionizing radiation and of contrast enhancement. B-mode US, and the microvascular pattern color Doppler are usually used as first step evaluation of parotid lesions. Elastography and contrast-enhanced US (CEUS) has opened further possible perspectives to improve the differentiation between benign and malignant parotid lesions. The characterization of the parotid tumors plays a crucial role for their treatment planning and for the prediction of possible surgical complications. We present, here an updated review of the most recurrent pathologies of parotid gland focusing on the diagnostic power of multiparametric US including CEUS and ultrasound elastography (USE); limitations, advantages and the main key-points will be presented

    Recovery of baseline renal function after treatment for prolonged in-stent artery thrombosis, in a COVID-19 positive patient: a case report

    No full text
    Objective: Acute renal in-stent thrombosis is common, especially after complex endovascular treatments, or in case of risk factors such as Covid-19 infection. Irreversible renal damage occurred when the renal artery was occluded for more than 3 hours. In this case, we present a case of renal function recovery after thromboaspiration of a renal stent thrombosis for more than 72 hours. Case presentation: A 88-year-old man who tested positive for COVID-19 presented to the emergency room with dyspnea and anuria. He referred a previous complex endovascular intervention with the triple chimney technique (ChEVAR). More than 72 hours passed between the onset of symptoms to the diagnosis of acute renal intra-stent thrombosis. He underwent urgent thromboaspiration with neurovascular devices returning to his baseline renal function. Conclusion: Despite the prolonged ischemia, renal revascularization with thromboaspiration restored renal function and rescued the remaining renal parenchyma

    Liver Transplant Imaging prior to and during the COVID-19 Pandemic

    No full text
    Background. The suspension of the surgical activity, the burden of the infection in immunosuppressed patients, and the comorbidities underlying end-stage organ disease have impacted transplant programs significantly, even life-saving procedures, such as liver transplantation. Methods. A review of the literature was conducted to explore the challenges faced by transplant programs and the adopted strategies to overcome them, with a focus on indications for imaging in liver transplant candidates. Results. Liver transplantation relies on an appropriate imaging method for its success. During the Coronavirus Disease 2019 (COVID-19) pandemic, chest CT showed an additional value to detect early signs of SARS-CoV-2 infection and other screening modalities are less accurate than radiology. Conclusion. There is an emerging recognition of the chest CT value to recommend its use and help COVID-19 detection in patients. This examination appears highly sensitive for liver transplant candidates and recipients, who otherwise would have not undergone it, particularly when asymptomatic

    Fully ultrasound-assisted endovascular aneurysm repair: preliminary report

    No full text
    Background: Reducing fluoroscopy times and iodine contrast administration during endovascular repair (EVAR) of infrarenal aortic aneurysms remains a challenge. The purpose of this study is to evaluate the preliminary results of a fully ultrasound-assisted EVAR without iodine contrast administration. Methods: Twenty-seven consecutive patients underwent an elective intravascular ultrasound (IVUS)eassisted EVAR with final contrast-enhanced ultrasound (CEUS) control of correct aneurysm exclusion. In no case intraprocedural injection of iodine contrast medium was performed. The primary study’s end points were the overall duration of the procedure, duration of fluoroscopy, cumulative radiation dose, the length of intraoperative CEUS control, and the comparison of findings between intraoperative CEUS and computed tomography (CT) scan at 1 month. Results: Mean duration of the procedure was 130 ± 35 min. Overall duration of fluoroscopy was 22 ± 18 min. Mean radiation dose was 66 mGy (range 24e82). The mean length of CEUS final control was 8 ± 2 min. No type I or type III endoleak was detected either at CEUS or at angio-CT scan at 1 month from EVAR. CEUS revealed a type II endoleak in 6 patients (22%), compared to 9 type II endoleaks (33%) detected at angio-CT scan 1 month after the procedure (P ¼ 0.5). Conclusions: Fully ultrasound (IVUS and CEUS)eassisted EVAR is safe, feasible, and reliable, completely eliminating the need for iodine contrast medium and reducing the radiation exposure for both patients and surgeons

    Median nerve evaluation by shear wave elastosonography: impact of "bone-proximity" hardening artifacts and inter-observer agreement

    No full text
    Peripheral nerves frequently travel close to the bone surface and are, therefore, prone to elastosonographic "bone-proximity" hardening artifacts. The impact of these artifacts on quantitative measurements of median nerve stiffness performed by shear wave elastosonography has not been explored. Our aim was to assess normal median nerve stiffness values at various locations

    The Underrated Role of Ultrasound in Peritoneal Dialysis

    No full text
    Ultrasound is very effective in performing procedures and assessment of complications in peritoneal dialysis. The ultrasound examination can be applied for preoperative assessment, during the peritoneal catheter placement, for the detection and monitoring of infection, as well as for the evaluation of the catheter malfunction. Despite being not only a cost- and time-saving technique but also a bedside procedure, ultrasonography remains an underrated clinical tool in the field of peritoneal dialysis. This publication wants to explain and reinforce the clinical utility of US in PD and to expand the diagnostic equipment for the clinician

    TIRADS, SRE and SWE in INDETERMINATE thyroid nodule characterization: Which has better diagnostic performance?

    No full text
    To assess Strain Ratio (SRE) and Shear Wave Elastography (SWE) accuracy alone and with TIRADS classification, for the risk stratification of indeterminate thyroid nodules

    US Evaluation of Topical Hemostatic Agents in Post-Thyroidectomy

    Get PDF
    Background: the aim of this study was to describe the ultrasound appearance of topical hemostatics after thyroidectomy. Methods: we enrolled 84 patients who were undergoing thyroid surgery and were treated with two types of topical hemostats, 49 with an absorbable hemostat of oxidized regenerated cellulose (Oxitamp®) and 35 with a fibrin glue-based hemostat (Tisseel®). All patients were examined using B-mode ultrasound. Results: In 39 patients of the first group (approximately 80%), a hemostatic residue was detected and in some cases confused with a native gland residue, or with cancer recurrence in oncological patients. No residue was detected in patients in the second group. The main ultrasound characteristics of the tampon were analyzed and arranged according to predefined patterns, and suggestions to recognize it and avoid wrong diagnoses were provided. A part of the group of patients with tampon residue was re-evaluated after 6–12 months, ensuring that the swab remained for months after the maximum resorption time declared by the manufacturer. Conclusions: with equal hemostatic effectiveness, the fibrin glue pad is more favorable in the ultrasound follow-up because it creates reduced surgical outcomes. It is also important to know and recognize the ultrasound characteristics of oxidized cellulose-based hemostats in order to reduce the number of diagnostic errors and inappropriate diagnostic investigations
    corecore